Key result
3D printing- and CT fusion-guided percutaneous closure successfully resolves severe mitral paravalvular leak.
Why the study?
Moderate to severe paravalvular leak increases mortality, and this report illustrates preprocedural planning with 3-dimensional printing and computed tomography image fusion to guide transcatheter closure of a giant paravalvular leak.
Case Report (n=1)
No
Preprocedural simulation with 3D-printed models combined with intraprocedural CT-fluoroscopy image fusion can facilitate accurate device sizing and first-attempt percutaneous closure of large, complex mitral paravalvular leaks.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for 3D-printed model and CT fusion guidance in complex mitral PVL closure; prospective validation required before adoption.
The presence of moderate to severe paravalvular leak increases mortality. We present a case of giant paravalvular leak closure using the 3-dimensional printing model to assess the success of the device to be used for its closure, computed tomography was performed for planning and guiding the procedure by image fusion. ( Level of Difficulty: Advanced. )
No takes yet. Share an insight, caveat, or question.
Espinoza-Rueda et al. (2021) conducted a case report in Severe mitral paravalvular leak with NYHA class III heart failure (n=1). Percutaneous paravalvular leak closure using an 18 x 10 mm Occlutech Paravalvular Leak Device guided by 3D-printed model planning and CT image fusion was evaluated on Successful percutaneous paravalvular leak closure and clinical improvement. Percutaneous closure guided by 3D printing and CT image fusion reduced severe mitral paravalvular leak to a slight residual leak with a 3 mm Hg mean gradient and resolved symptoms at 15 days.
Synapse has enriched 10 related papers. Consider them for comparative context: