Answers are grounded in this paper and cite their sources.
INTRODUCTION: Accurate preoperative localization of parathyroid adenomas is essential for minimally invasive focused parathyroidectomy inpatients with primary hyperparathyroidism (PHPT). Technetium-99m sestamibi ([99mTc]Tc-MIBI) scintigraphy is routinely performed usinga variety of imaging protocols, including dual-phase planar imaging and single-photon emission computed tomography/computed tomography(SPECT/CT); however, an optimal standardized protocol has not yet been established. This study aimed to directly compare the diagnosticperformance of dual-phase planar scintigraphy, early SPECT/CT, and delayed SPECT/CT for the localization of parathyroid adenomas. MATERIAL AND METHODS: In this retrospective single-center study, 94 examinations in patients with biochemically confirmed PHPT who underwent [99mTc]Tc-MIBI scintigraphy between July 2020 and June 2023 were included. All patients underwent histopathological verification(adenoma or negative findings). Imaging datasets were categorized into three protocols: dual-phase planar imaging, early SPECT/CTat 20 minutes, and delayed SPECT/CT at 120 minutes. Each dataset was independently evaluated by three blinded nuclear medicinephysicians. A scan was considered positive when at least two readers identified a concordant lesion. Sensitivity, specificity, and predictivevalues were calculated with 95% confidence intervals (CIs; Wilson method). Paired comparisons were performed using McNemar's test. RESULTS: Eighty-four of 94 patients (92.7%) were confirmed to have parathyroid adenomas. The sensitivity was 73.8% (95% CI 63.5-82.0%) for dual-phase planar imaging, 78.6% (95% CI 68.6-86.0%) for early SPECT/CT, and 82.1% (95% CI 72.6-88.9%) for delayed SPECT/CT. The corresponding specificity values were 50.0% (95% CI 23.7-76.3%), 60.0% (95% CI 31.3-83.2%), and 50.0% (95% CI 23.7-76.3%), respectively.Delayed SPECT/CT demonstrated significantly greater sensitivity than dual-phase planar imaging (p = 0.01) and early SPECT/CT(p = 0.02), whereas differences in specificity were not statistically significant (p > 0.05). Interobserver agreement was moderate acrossall protocols (κ = 0.40-0.56). CONCLUSIONS: Delayed SPECT/CT provides the highest sensitivity for the preoperative localization of parathyroid adenomas among the evaluated [99mTc]Tc-MIBI protocols. These findings support the inclusion of delayed SPECT/CT as a key component of parathyroid scintigraphy protocols and highlight the need for standardized imaging approaches. Prospective multicenter studies are warranted tovalidate these results.
No takes yet. Share an insight, caveat, or question.
Kocemba et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: