Answers are grounded in this paper and cite their sources.
P-wave velocity is a non-destructive test (NDT) commonly used in several disciplines (archaeology, restoration, geology, civil engineering, etc.). This test has different measurement techniques (direct, semi-direct and indirect) and there is limited information about the correlations between these methods. With this aim, relationships between different P-wave velocity measurement techniques were researched using 123 square prism samples with dimensions of 10 x 10 x 18 cm prepared from 41 different rock types (plutonic, volcanic, pyroclastic and sedimentary). According to the results, high coefficients of determination (R^2: 0.872–0.910) were determined for simple regression relationships between the different P-wave velocity measurements. Among the different P-wave velocity measurement methods, the highest P-wave velocity was measured with the semi-direct method, whereas the indirect method generally yielded the lowest values. For multiple regression correlations between the three different measurement methods, the coefficients of determination (R^2) varied from 0.898 to 0.928.
No takes yet. Share an insight, caveat, or question.
Karakaya et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: