Why the study?
Paper-printed 12-lead ECGs remain the dominant archival format, yet retrospective studies and machine learning pipelines require millivolt-time signals rather than pixel images. Existing digitizers treat grid removal as a dedicated preprocessing stage that requires retuning across paper types and scanners.
Population
109 standard and 125 pathology-enriched PTB-XL rendered records, plus 430 real archival ECG scans
Comparison
Direct vectorization pipeline evaluated across standard 4x3 vs dense single-column layouts and pristine vs distorted renders
Design
Algorithm development and validation study
Answers are grounded in this paper and cite their sources.
Demonstrates rapid paper electrocardiogram digitization using color masking and rigid comb tracking, indicating utility for research.
Paper-printed 12-lead electrocardiograms remain the dominant archival format in large cardiology cohorts; yet, retrospective studies and machine learning pipelines need millivolt–time signals rather than pixel images. Existing digitizers treat grid removal as a dedicated preprocessing stage that must be re-tuned across paper types and scanners. We present a preprocessing-free pipeline built on three structural facts: printed grids and annotations are chromatic while the trace is near-achromatic; the page holds N parallel lead strips at uniform vertical pitch; and each lead’s baseline is well-approximated by a straight line once the page is oriented. A LAB-chromaticity mask removes grid and annotation ink at the pixel level; a rigid comb of N impulses anchors all lead baselines simultaneously; and a continuity-weighted column search tracks each trace, with a second pass recovering QRS spikes clipped by the half-pitch hard cap. On 109 PTB-XL records rendered through ecg-image-kit, the pipeline reaches median Pearson r=0.987 (RMSE 0.029 mV, SNR 14.6 dB) on standard 4×3 renders. On dense single-column renders, it reaches only r=0.667 with a ±50 ms alignment window (0.703 with an unrestricted lag search, which partly matches the wrong beat), mainly because tall waves cross into neighboring rows. With added wrinkles, yellowing, noise, rotation and cropping, median r is 0.966 (mean 0.889, SNR 11.2 dB) and stable across three independent distortion draws; a pathology-enriched set of 125 records (infarction, ST/T change, conduction disturbance, hypertrophy, arrhythmia) gives a median r of 0.989 pristine and 0.970 distorted. Scored without any generator metadata, from the printed calibration pulse and the standard lead order, the results are unchanged (median r=0.987 pristine, 0.962 distorted). An ablation shows that the chromaticity mask carries most of the accuracy. On 430 real archival scans, the pipeline runs without retuning (≈3 s/page, one CPU core), and the rigid comb returns a regularly spaced twelve-band set on 76.7% of pages, but a signal-content test (Einthoven/Goldberger identities) shows it localizes the limb leads no better than peak detection. Use of real scans has two open limitations: waveform accuracy on real scans has not been measured against ground-truth, and the orientation stage leaves 98% of auditable archival pages upside-down, which reverses lead identity. The results support research use on standard-layout prints, not clinical use. A page-level polarity heuristic used in an earlier version of the pipeline, now disabled, is shown to cause nearly all whole-record failures previously attributed to paper warp. Code and all evaluation scripts are released.
No takes yet. Share an insight, caveat, or question.
Cojocariu et al. (2026) studied this question.