This is the authors' abstract. We don't add key points for this paper.
Remote respiratory-rate (RR) estimation from video is usually framed as a modelling problem and reported as one number; we treat it as a measurement problem. Using COHFACE (39 subjects, 160 clips) and VitalVideos (39 clips), both seated, we compare untrained colour channels over facial and torso regions with trained two-stream models on subject-disjoint five-fold splits, with held-out rows scored once. An untrained torso chrominance channel reaches a mean absolute error (MAE) of 1.267 breaths/min (r=+0.795), while every facial channel stays at noise level (3.69–3.91) against a 2.644 same-row blind baseline. Background patches average 4.36 and a neighbouring region 2.58, so the signal is not illumination but region-specific. Motion from sub-pixel displacement fails alone (2.92), and removing it from the colour signal does not degrade the estimate (1.156): the mechanism is narrowed, not excluded. Per-window selection lowers fusion error from 3.439 to 2.463 but stays worse than carrying a person’s last measurement forward (1.438, on 70% of rows) and no better than the blind baseline; with overlapping windows, that test is descriptive only. The comparison covers the projections, regions and estimator tested here.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Buyung et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: