Key result
Unidirectional fenestrated valved patch repair yields uneventful recovery in high-PVR aortopulmonary window.
Case Report (n=1)
Demonstrates the technical feasibility and uneventful postoperative recovery of using a unidirectional, fenestrated, valved aorticopulmonary fabric patch via Johansson's transwindow approach in a pediatric patient with type I aortopulmonary window and severe pulmonary arterial hypertension.
Answers are grounded in this paper and cite their sources.
May support feasibility of valved patch in select high-PVR cases; leaves open need for larger prospective studies.
A 10-year-old female patient diagnosed with isolated type I aortopulmonary window and severe pulmonary arterial hypertension who underwent repair of the aortopulmonary window via Johansson's transwindow approach using a unidirectional, fenestrated, valved, aorticopulmonary patch. The preoperative pulmonary vascular resistance was 9.0 Woods units/m2 that reduced to 4.0 Woods units/m2 after oxygen (100%) and nitric oxide (80 ppm) administration. The postoperative recovery was uneventful.
No takes yet. Share an insight, caveat, or question.
Chowdhury et al. (2022) conducted a case report in Isolated type I aortopulmonary window and severe pulmonary arterial hypertension (n=1). Repair of aortopulmonary window via Johansson's transwindow approach using a unidirectional, fenestrated, valved, aorticopulmonary fabric patch (UKC's modification) was evaluated on Postoperative recovery. Transwindow unidirectional fenestrated valved patch repair resulted in uneventful recovery in a 10-year-old girl with aortopulmonary window and baseline PVR of 9.0 Woods units/m2.