Answers are grounded in this paper and cite their sources.
Frameless torque motors are attractive for humanoid and collaborative robot joints because the stator and rotor can be integrated directly into the load-bearing structure, thereby combining a compact axial envelope, low rotor inertia, and a hollow passage for cables or cooling. This study develops and applies a coupled electromagnetic, thermal, and structural workflow to an 18-slot/20-pole frameless permanent-magnet synchronous motor supplied from a 48 V DC bus and rated at 460 W, 1.75 N·m, and 2500 rpm. Calibrated two-dimensional finite-element models in Ansys Maxwell with 3D end-winding leakage and axial fringing corrections are combined with map-based and lumped-parameter thermal models in Ansys Motor-CAD and electromagnetic-force-wave evaluation in Ansys Mechanical. The numerical assessment includes the no-load field, air-gap flux density, back electromotive force and its harmonics, cogging torque, rated and overload operation, losses, efficiency maps, temperature- and current-dependent demagnetisation, transient and steady-state temperatures, and vibration-related force indicators. At the rated operating point, the predicted mean torque is 1.7518 N·m with 3.03% peak-to-peak ripple. The cogging-torque amplitude is 1.833 mN·m (0.105% of rated torque), while the phase back-EMF total harmonic distortion is 5.68% and is dominated by the third harmonic. The peak map efficiency is 90.91%; the rated-point map shaft efficiency is 86.61% (accounting for temperature-corrected copper loss and mechanical/windage losses at thermal equilibrium), whereas the cold electromagnetic-only efficiency at 20 °C is 87.6%. An overload capability point of 4.00 N·m is obtained at 30.63 A (with a transient peak torque reaching 4.03 N·m at 30.5 A), whereas the rated-load thermal model predicts a winding hot spot of 106 °C and a magnet temperature of 96 °C. Under continuous rated operating conditions, the maximum radial electromagnetic force density reaches 0.594 MPa (593,677 N/m2). The near-unity saliency ratio (Lq/Ld ≈ 1.01) shows that the investigated rotor is a surface-mounted or shallow-inset PMSM and that its reluctance-torque contribution is negligible. These results identify local saturation, rated efficiency, and the second-order radial-force mode as the main design constraints. A same-envelope IPM-SynRM rotor with multilayer flux barriers is consequently identified as a subsequent comparison case rather than presented as a validated result. All performance values reported here are numerical simulation predictions that establish a multiphysics design baseline, requiring prototype experimental validation.
No takes yet. Share an insight, caveat, or question.
Chi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: