Answers are grounded in this paper and cite their sources.
SIMULATED, NOT MEASURED design/bound study. From P- and S-wave speeds, stated latency budgets, and MEMS noise floors (phone-grade and ~US$100 dedicated nodes), this paper computes the warning time a low-cost earthquake early warning network delivers versus epicentral distance, magnitude, and node density; derives blind-zone radii of about 15 km (dedicated) and 25 km (phone) inside which no warning is possible at any density; shows node density past ~1 per 100 km2 buys almost no time; and costs the false-alarm rate of fast triggering in the same arithmetic. All numbers reproduce from the archived compute script.
No takes yet. Share an insight, caveat, or question.
William Alexander Aldred (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: