We propose a passivity-informed data-driven predictive control framework based on passivity-preserving sampling of unknown continuous-time linear systems. We incorporate the passive supply rate into the objective functional alongside an output-regulation cost, thereby explicitly accounting for energy extraction. Despite being practically motivated, the resulting objective is not always convex; its convexity depends on the collected input-output training data. We exploit passivity-induced positive semidefiniteness to derive an equivalent reformulation that remains a convex quadratic program independently of the data. Furthermore, we establish recursive feasibility and asymptotic output convergence using passivity and a terminal equality constraint. Numerical simulations illustrate the closed-loop performance and computational benefits of the proposed approach.