Answers are grounded in this paper and cite their sources.
A complete, closed first-principles sizing of a village chlorination system that needs no chlorine supply chain: a photovoltaic array powers a brine electrolyser producing sodium hypochlorite from salt and water, stored under a stated decay law and dosed against a stated chlorine demand and distribution residual decay. For a 10 m3/day supply the required tank dose is 1.185 mg/L, decay-corrected production is 13.65 g of chlorine per day at 4.652 kWh/kg, requiring 63.5 Wh/day (14.1 Wp in theory, a 50 Wp module in practice) and 45.0 g of salt per day; hypochlorite storage decay at 30 C forces a production oversize factor of 1.152. All results are simulated, not measured; nothing described has been built or tested. Computations are reproducible from the deposited compute.py and results.json.
No takes yet. Share an insight, caveat, or question.
William Alexander Aldred (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: