Answers are grounded in this paper and cite their sources.
System observation capabilities through internet connectivity [6].Puskesmas Makrayu Palembang, as a primary healthcare facility, provides various healthcare services such as immunization programs, maternal and child healthcare, Posyandu activities, and general medical examinations.However, service information is still disseminated through conventional media such as bulletin boards and direct announcements.These methods often result in delayed information updates and limited accessibility for visitors.In addition, environmental information such as temperature and air quality is not currently integrated into the public information system, despite its importance for healthcare environments, particularly for patients with respiratory conditions.Therefore, a more effective and integrated information management system is required to improve AbstractThe development of Internet of Things (IoT) technology has created new opportunities for improving information management and environmental monitoring in healthcare facilities.Puskesmas Makrayu Palembang currently relies on conventional information dissemination methods, resulting in limited accessibility and inefficient information updates.This study aims to design and implement a website-based information management and environmental monitoring system using Arduino Uno as the main controller and ESP32 as the communication module.The proposed system integrates a website-based information management platform, Firebase Realtime Database, P10 LED matrix display, DHT22 temperature sensor, MQ135 air-quality sensor, and buzzer notification mechanism within a unified IoT architecture.The research adopted a system development approach consisting of literature study, field observation, system requirement analysis, system design, implementation, and testing.The implementation results demonstrated that website data synchronization, Firebase communication, ESP32 connectivity, LED matrix display operation, sensor integration, and overall system integration were successfully achieved during prototype testing.Information entered through the website could be displayed correctly on the running-text display in real time, while environmental information obtained from the DHT22 and MQ135 sensors could be processed and displayed simultaneously.The evaluation focused on functional verification of communication, synchronization, display operation, and sensor integration within a prototype environment.However, the system was evaluated only at the prototype level due to limited deployment opportunities and research time constraints, and therefore does not yet fully represent continuous operational conditions in healthcare facilities.Consequently, aspects such as long-term ESP32-Firebase communication stability, data transmission latency, system consistency under prolonged operation, and performance under high communication loads were not evaluated in this study.The proposed system nevertheless provides a practical foundation for integrated healthcare information management and environmental monitoring applications in primary healthcare facilities.
No takes yet. Share an insight, caveat, or question.
Ramadanti et al. (2026) studied this question.
Synapse has enriched 4 related papers. Consider them for comparative context: