Key result
Snare-assisted delivery enables successful TAVR passage across a severely calcified aortic arch.
Why the study?
A dense calcified mass in the outer curvature of a severely calcified aortic arch can prevent advancement of the delivery catheter during transfemoral transcatheter aortic valve replacement.
Case Report (n=1)
No
Demonstrates that snare-assisted delivery grasping the stiff wire and delivery catheter nose cone can facilitate passage of a self-expanding TAVR prosthesis across a severely calcified aortic arch without major aortic complications.
Answers are grounded in this paper and cite their sources.
Snare-assisted delivery may enable TAVR completion in severe arch calcification; leaves open safety and reproducibility in larger series.
An 89-year-old woman underwent transfemoral transcatheter aortic valve replacement with a 26-mm Evolut PRO (Medtronic, Minneapolis, MN, USA) bioprosthesis because of severe aortic stenosis.As shown in Figure 1, the delivery catheter failed to pass through the severely calcified aortic arch, because of a dense calcified mass in the outer curvature of the aortic arch (Supplementary Video 1).Eventually, a snare-assisted delivery using a 35-mm loop Amplatz Goose Neck Snare kit (ev3 Endovascular, Inc., Plymouth, MN, USA) was attempted.We tightened the snare to grasp and retain the stiff wire and the nose cone of the delivery catheter.Further, we advanced the delivery catheter while simultaneously pulling the snare catheter downward.Finally, the delivery catheter was passed and the valve implantation was successful without major aortic complications (Supplementary Videos 2 and 3).
No takes yet. Share an insight, caveat, or question.
Kaneko et al. (2020) conducted a case report in Severe aortic stenosis with a severely calcified aortic arch (n=1). Snare-assisted valve delivery using a 35-mm loop snare kit during transfemoral TAVR with a 26-mm bioprosthesis was evaluated on Successful delivery catheter passage and valve implantation without major aortic complications. Snare-assisted delivery using a 35-mm loop snare successfully enabled passage of a 26-mm TAVR bioprosthesis across a calcified aortic arch in an 89-year-old woman without major aortic complications.
Synapse has enriched 10 related papers. Consider them for comparative context: