Key result
Transjugular 3D ICE guides successful EVOQUE TTVR in carcinoid heart disease.
Why the study?
Successful transcatheter tricuspid valve replacement (TTVR) with the EVOQUE system relies on fluoroscopic and transesophageal echocardiography (TEE) guidance, but TEE imaging may be inadequate and require adjunctive intracardiac echocardiography (ICE).
Case Report (n=1)
No
Transjugular 3D intracardiac echocardiography provides an effective alternative imaging route for guiding transcatheter tricuspid valve replacement without interfering with the valve delivery system when transesophageal echocardiography views are limited by acoustic shadowing.
Answers are grounded in this paper and cite their sources.
May facilitate TTVR in select complex cases; leaves open need for validation before wider adoption.
BACKGROUND: Transcatheter tricuspid valve replacement (TTVR) with the EVOQUE system was the first Food and Drug Administration-approved TTVR therapy for clinical use in patients with symptomatic severe tricuspid regurgitation. Successful implantation is largely dependent on both fluoroscopic and transesophageal echocardiography (TEE) guidance. Imaging by TEE may be inadequate for confident and successful TTVR, which has led to adjunctive imaging with intracardiac echocardiography (ICE). CASE SUMMARY: We present a unique case of TTVR with the EVOQUE system using transjugular 3-dimensional (3D) ICE guidance in symptomatic severe tricuspid regurgitation due to carcinoid syndrome in the setting of cardiogenic shock. DISCUSSION: Transjugular 3D ICE is an effective adjunctive imaging modality for TTVR in patients who have inadequate imaging on TEE. TAKE-HOME MESSAGE: A transjugular approach for 3D ICE offers an alternative route compared with transfemoral for real-time visualization of the tricuspid valve leaflets with no interference with the valve delivery system.
No takes yet. Share an insight, caveat, or question.
Keppel et al. (2026) conducted a case report in Symptomatic severe tricuspid regurgitation due to carcinoid syndrome and moderate aortic stenosis in the setting of cardiogenic shock (n=1). Transcatheter tricuspid valve replacement (EVOQUE system) with transjugular 3D intracardiac echocardiography guidance was evaluated on Procedural success of EVOQUE tricuspid valve implantation. Transjugular 3D intracardiac echocardiography enabled complete tricuspid valve leaflet visualization and successful EVOQUE TTVR in an 81-year-old man with carcinoid heart disease.
Synapse has enriched 10 related papers. Consider them for comparative context: