Background/Objectives: Cone-beam computed tomography (CBCT) is widely used in dentomaxillofacial imaging for evaluating bone grafts and implant-related procedures; however, image quality is often compromised by metal-induced artefacts. This study compared CBCT, photon-counting detector CT (PCD-CT), and micro-computed tomography (µCT) for imaging clinically relevant bone graft materials and three-dimensional printed calcium phosphate scaffolds, focusing on biomaterial visualisation and titanium artefact reduction. Methods: Four bovine mandibles were prepared with standardized cylindrical defects containing eight bone substitute materials and 3D-printed calcium phosphate scaffolds, with or without surrounding titanium cages. Specimens were imaged using CBCT and PCD-CT with low-dose and maximum-dose ultra-high-resolution acquisition protocols, and µCT. Two readers independently assessed image interpretability, biomaterial visualisation, and metal artefact severity using a five-point scoring system. Inter-reader agreement was evaluated using weighted Cohen’s kappa. Results: µCT provided the highest spatial resolution and served as the ex vivo reference standard. Under the acquisition and reconstruction protocols evaluated, PCD-CT provided favorable visualization of scaffold architecture and reduced the visual impact of titanium-induced artefacts compared with CBCT. High-energy virtual monoenergetic reconstructions (≥130 keV) further reduced beam-hardening and streak artefacts, although the optimal reconstruction energy may depend on the biomaterial and diagnostic task. Without titanium cages, PCD-CT and µCT achieved higher image interpretability scores than CBCT. With titanium cages, CBCT frequently became non-diagnostic, whereas PCD-CT maintained good visualisation of most biomaterials. Inter-reader agreement ranged from substantial to almost perfect. Conclusions: In this exploratory ex vivo study, the evaluated PCD-CT protocols provided favorable qualitative visualization of several bone graft materials and three-dimensional printed calcium phosphate scaffolds compared with the evaluated CBCT protocol, particularly in the presence of titanium cages. However, the protocols were not dose-matched, and differences in acquisition and reconstruction parameters prevent attributing the observed findings exclusively to detector technology. The study does not establish PCD-CT superiority at equivalent radiation doses or demonstrate clinical performance in longitudinal bone-regeneration monitoring. Further dose-matched studies incorporating objective image-quality measurements and clinical validation are required.
No takes yet. Share an insight, caveat, or question.
Guerrero et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: