Key result
Deep Health plantar platform achieves ~0 mmHg BP bias compared to auscultation.
Why the study?
Resting agreement between wearable sensors and clinical reference standards does not establish fidelity during dynamic cardiovascular exertion, and software-imported blood pressure logs do not represent direct hemodynamic sensing.
Does a fixed ground-contact plantar multi-sensor platform and finger/wrist-worn photoplethysmography wearables accurately measure stationary blood pressure and resting/dynamic heart rate compared to manual brachial auscultation and radial pulse counts in adults?
Observational (n=483)
Does a fixed ground-contact plantar multi-sensor platform and finger/wrist-worn photoplethysmography wearables accurately measure stationary blood pressure and resting/dynamic heart rate compared to manual brachial auscultation and radial pulse counts in adults?
A fixed plantar multi-sensor platform achieved sub-millimeter-of-mercury blood pressure agreement and high heart rate accuracy at rest compared to manual auscultation, whereas commercial finger and wrist PPG wearables demonstrated substantial heart rate lag and individual-level error during treadmill exercise.
Answers are grounded in this paper and cite their sources.
Clinicians should interpret dynamic HR from finger/wrist wearables cautiously during exercise; leaves open need for improved validation in active settings.
ABSTRACTBackground: Resting agreement between wearable sensors and clinical reference standards does not establish fidelity during dynamic cardiovascular exertion, nor do software-imported blood pressure logs represent direct hemodynamic sensing. This study evaluated stationary blood pressure (BP) and heart rate (HR) agreement of a fixed ground-contact plantar platform alongside resting and dynamic treadmill HR tracking of finger-worn (OURA) and volar wrist-worn (WHOOP) photoplethysmography (PPG) devices in an established user cohort. Methods: In 483 adults (267 women, 216 men) recruited from active personal owners with mature device baselines, the Deep Health® plantar platform (model PH-CS20C3) was compared concurrently against manual brachial auscultation and 60-second radial pulse counts during quiet stance. OURA and WHOOP HR outputs were evaluated at rest and across a 30-minute treadmill protocol (8:00 min/mile [7.5 mph], 2.0° incline) sampled at baseline and every 3 minutes (5,313 paired observations per wearable). Agreement was assessed via mean bias (MD), standard deviation of differences (SDD), Bland–Altman 95% limits of agreement (LoA), mean absolute error (MAE), root mean square error (RMSE), Lin’s concordance correlation coefficient (CCC), and 10,000-iteration participant-level bootstrap confidence intervals. Wearable BP entries were excluded from primary accuracy testing because audit confirmed they reflected static external cuff imports or uncalibrated overnight estimates rather than contemporaneous sensor measurements. Results: Stationary plantar SBP and DBP biases were both −0.01 mmHg, with SDDs of 1.09 mmHg (95% LoA: −2.15 to +2.13 mmHg; CCC = 0.9890) and 0.75 mmHg (95% LoA: −1.48 to +1.45 mmHg; CCC = 0.9932), respectively, with 93.8% of SBP and 99.6% of DBP readings falling within ±2.0 mmHg of manual auscultation. Stationary plantar HR bias was +0.04 bpm (MAE = 0.34 bpm), whereas stationary OURA and WHOOP HR MAEs were 8.50 and 13.85 bpm. During treadmill exercise, reference HR surged by +60.38 bpm at minute 3 (145.51 bpm), whereas OURA and WHOOP lagged at 134.04 bpm (MD = −11.47 bpm) and 135.23 bpm (MD = −10.28 bpm). Across minutes 3–30, overall exercise MAE was 8.43 bpm (95% CI: 8.27–8.59) for OURA and 7.66 bpm (95% CI: 7.50–7.81) for WHOOP. During late exercise (minutes 12–30), cohort mean signed errors converged near zero (+0.81 bpm for OURA; +0.08 bpm for WHOOP), yet individual MAEs remained persistently elevated at 8.37 and 7.56 bpm, with 32.6% of OURA and 24.4% of WHOOP readings exceeding ±10 bpm error. Conclusions: The Deep Health® plantar platform achieved sub-millimeter-of-mercury agreement with manual auscultation during quiet stance within the normotensive-to-prehypertensive range studied. Conversely, consumer upper-limb wearables exhibited severe initial algorithmic lag during rapid exertion and substantial participant-level error dispersion during sustained running that was masked by near-zero group mean bias. Furthermore, neither ring nor wrist PPG platforms possess the physical counter-bearing or hydrostatic transduction architecture required for instantaneous, uncalibrated blood pressure measurement.
No takes yet. Share an insight, caveat, or question.
Weng et al. (2026) conducted an observational in Normotensive-to-prehypertensive adults undergoing stationary blood pressure and dynamic exercise heart rate evaluation (n=483). Deep Health plantar platform (PH-CS20C3), OURA ring, and WHOOP wrist strap vs. Manual brachial auscultation and 60-second radial pulse counts was evaluated on Stationary blood pressure and resting/dynamic heart rate agreement (MD -0.01 mmHg, 95% CI -2.15 to 2.13). The Deep Health plantar platform had -0.01 mmHg SBP/DBP bias vs auscultation, while OURA and WHOOP showed exercise HR MAEs of 8.43 and 7.66 bpm.