Answers are grounded in this paper and cite their sources.
Plasma physics and nuclear fusion research in Thailand are entering a significant phase at the Thailand Institute of Nuclear Technology (Public Organization) (TINT), which operates the Thailand Plasma Focus-2 (TPF-2) and has received, for the Thailand Tokamak-1 (TT-1) project, major equipment from the HT-6 M machine through cooperation with the Institute of Plasma Physics, Chinese Academy of Sciences (ASIPP), People’s Republic of China. The efficient operation of the TT-1 device primarily depends on the development of four main systems, of which the Plasma Control System (PCS) and Data Acquisition (DAQ) systems are considered critical systems that must be learned and newly developed to support future technologies. This research, therefore, aims to develop and integrate the PCS and DAQ systems on the LabVIEW platform combined with National Instruments (NI) PXIe hardware using the TPF-2 as an engineering testbed that may inform future TT-1 development. The focus is on solving electromagnetic interference (EMI) and severe ground potential rise (GPR) phenomena from discharges at the hundreds-of-kiloamperes level that distort control signals and cause damage to electronic equipment. We developed a multi-tiered grounding architecture according to IEEE Standard 1100 in order to isolate the sensitive diagnostic loops from high-current return paths. This setup includes the diagnostic (DG), working (WG), and shielding networks, and uses optocoupler-based galvanic isolation to protect low-voltage electronics. The transient WG–DG potential difference was not measured. Original signal recovery is handled by a dual-stage technique that combines amplitude limiting with Savitzky-Golay filtering. After the modification, the recorded transient noise within the 10–60 MHz band was more than tenfold lower. The 5 V-referenced interference ratio at the HVPS analog input of the microcontroller rose from − 4.78 ± 2.21 dB to 13.09 ± 1.68 dB (mean ± sample standard deviation, n = 40 shots per configuration; operating points not matched). The clean signal path was used to capture the plasma pinch dynamics at an operating voltage of 11 kV and a peak current of about 120 kA, on a current scale that relies on an uncalibrated coil mutual inductance and unverified equal current sharing, so its dominant uncertainty is unquantified. The measured current waveforms were used to calibrate Lee Model Code simulations, with which they are consistent. Up to 465 shots per day were recorded without observed malfunction. These integration techniques yield a potential technical reference for developing control architectures for the TT-1 device.
No takes yet. Share an insight, caveat, or question.
Bor‐in et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: