Background Prediction of a future laboratory abnormality depends on whether it is measured. We examined whether an early intensive care model predicts documented low phosphate across different repeat-testing practices, and what selective testing leaves unresolved. Methods Models were developed in MIMIC-IV 3.1 and evaluated after freezing in eICU-CRD 2.0. Eligible adults remained in intensive care at six hours, had phosphate available by then, and had no baseline specimen below 2.0 mg/dL (approximately 0.65 mmol/L); some baseline specimens were reported later. The endpoint was a recorded low result from a specimen collected after six hours and by discharge or 48 hours; reporting could occur later. Primary evaluation was conditional on repeat testing. Penalized logistic regression using available laboratory results, age and sex was compared with phosphate alone. Internal patient and external hospital-cluster bootstraps quantified uncertainty. Observation analyses included testing patterns, inverse-probability weighting and extreme assignments of unknown labels. Results Of 31118 eligible MIMIC patients, 26469 (85.1%) were retested, with 2934 events (11.1%). Of 15568 eligible eICU patients from 186 hospitals, 10133 (65.1%) were retested, with 1646 events (16.2%). Internal area under the receiver operating characteristic curve was 0.716. Externally, it was 0.717 (95% confidence interval 0.704–0.735), area under the precision-recall curve was 0.330 (0.304–0.368), Brier score was 0.125 (0.117–0.135), and calibration slope was 0.827 (0.754–0.914). The paired external discrimination gain over phosphate alone was 0.067 (0.054–0.083). Weighting under conditional missing-at-random assumptions yielded an external discrimination estimate of 0.712. Hypothetically assigning all untested eICU patients a binary assay label of zero or one gave a completion range of 10.6%–45.5%; this does not bound biological incidence. Conclusions The model retained moderate discrimination for documented low phosphate among retested patients. Imperfect external calibration, selective ascertainment and retrospectively determined eligibility limit clinical use. Prospective evaluation requires systematic outcome measurement and a defined clinical action; these data do not establish that tests can safely be omitted.
No takes yet. Share an insight, caveat, or question.
Tianyi Yu (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: