Answers are grounded in this paper and cite their sources.
Background Intrinsic capacity is a core indicator of healthy aging; however, assessment tools specifically designed for older Chinese patients with stroke remain lacking. This study aimed to develop a culturally appropriate intrinsic capacity assessment scale for older patients with stroke and to evaluate its psychometric properties. Methods The item pool was developed through a literature review and descriptive qualitative semi-structured interviews. Two rounds of Delphi consultation were conducted to refine the items. A cross-sectional survey was carried out between January and May 2024 among older inpatients with stroke at a tertiary general hospital in China. Item screening was performed using response distribution, critical ratio, item-total correlation, and exploratory factor analysis (EFA). Psychometric properties were evaluated using Cronbach’s α , split-half reliability, test-retest reliability, the content validity index (CVI), EFA, and confirmatory factor analysis (CFA). Results The initial scale contained 24 items across five dimensions. After the first round of Delphi consultation, one item was deleted, 16 items were revised, and eight items were added, yielding 31 items; after the second round, one item was deleted and two items were revised, yielding 30 items for psychometric testing. The expert authority coefficients were 0.90 and 0.93, respectively, with significant Kendall’s W values ( P < 0.05). A total of 623 questionnaires were distributed, and 617 valid questionnaires were returned (effective response rate, 99.03%). One item was deleted after EFA, yielding a final 29-item scale with five dimensions. Five factors were extracted, explaining 71.08% of the total variance. CFA showed acceptable model fit ( χ ²/df = 2.472, RMSEA = 0.065, NFI = 0.886, IFI = 0.930, TLI = 0.915, CFI = 0.929). The overall Cronbach’s α was 0.961 (range across dimensions, 0.873–0.946); total split-half reliability was 0.877, total test-retest reliability was 0.949, the S-CVI was 0.977, and item-level CVI values ranged from 0.83 to 1.00. Conclusions The scale demonstrated satisfactory reliability and validity and is suitable for the Chinese cultural and clinical context. It can be used to assess intrinsic capacity in older patients with stroke in clinical practice, although further multicenter validation is needed.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: