Answers are grounded in this paper and cite their sources.
Background: Tuberculosis (TB) remains a major public health concern, and timely diagnosis is essential for initiating treatment and reducing transmission.Ziehl-Neelsen (ZN) smear microscopy remains widely used in resource-limited settings because of its simplicity and low cost; however, its sensitivity is limited, particularly in patients with a low bacillary burden.Truenat® Mycobacterium tuberculosis (MTB) rapid molecular diagnostic assay (Molbio Diagnostics Limited, Verna, Goa, India) can detect M. tuberculosis directly from respiratory specimens and can be followed by testing for rifampicin (RIF) resistance.Methodology: This retrospective comparative diagnostic study was conducted in the Department of Microbiology at N.K.P. Salve Institute of Medical Sciences & Research Centre and Lata Mangeshkar Hospital, Nagpur, Maharashtra, India, from April 2023 to March 2026.A total of 3,314 respiratory specimens (sputum samples) from patients clinically suspected of pulmonary TB were tested using both ZN smear microscopy and the Truenat MTB assay.Truenat-positive specimens were additionally tested for RIF resistance using the Truenat MTB-RIF assay.Diagnostic performance measures, including sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), were calculated using ZN microscopy as a comparator because a definitive reference standard such as mycobacterial culture was unavailable.Results: Among 3,314 respiratory sputum samples, ZN microscopy detected acid-fast bacilli in 73 (2.20%), while Truenat MTB detected M. tuberculosis in 117 (3.53%).All ZN-positive specimens were also positive by Truenat, while 44 (1.33%) additional cases were detected by Truenat among ZN-negative specimens.Agreement between the two methods was substantial (Cohen's κ = 0.762; 95% CI, 0.694-0.830),and McNemar's test showed a statistically significant difference in paired detection rates (χ² = 42.023;p < 0.001; absolute difference 1.33 percentage points; 95% CI, 0.93-1.73).Because ZN microscopy is not a reference standard, these values represent concordance with microscopy only and not diagnostic accuracy against culture.Conclusions: In this retrospective laboratory-based evaluation, Truenat MTB demonstrated a higher detection yield than ZN smear microscopy and identified additional cases that were missed by conventional microscopy.Its ability to provide rapid molecular detection and RIF resistance testing may offer important advantages for TB diagnosis and early identification of drug-resistant disease.Because no culture or other accepted reference standard was available, the diagnostic accuracy of Truenat MTB could not be independently established; prospective culture-referenced studies are warranted.
No takes yet. Share an insight, caveat, or question.
Ganvir et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: