Answers are grounded in this paper and cite their sources.
Intraoperative hypotension, hypoxemia, and related derangements are associated with postoperative organ injury, yet existing predictors target a single event and require invasive or specialized monitoring. A temporal convolutional model using only flowsheet vital signs and the drug administration record was developed on 3,724 noncardiac surgical cases from the open VitalDB registry and evaluated, frozen, on 9,720 cases from an independent academic medical center. Ten hemodynamic, respiratory, and thermal events were predicted at 3-, 5-, and 10-min horizons. Mean area under the receiver operating characteristic curve at 5 min, restricted to windows in which the patient was not already breaching the threshold, was 0.887 internally and 0.843 externally. At two alarms per case-hour, sensitivity was 0.61 and positive predictive value 0.27 internally, with a median lead time of 3.8 min that was unchanged externally. Alarm precision was modest and unusable externally for hypoxemia, supporting feasibility rather than clinical readiness.
No takes yet. Share an insight, caveat, or question.
Stephen et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: