Design blueprint derived from the source paper (DOI 10.5281/zenodo.24155126): This paper presents a computed design for a pulsed coherent Doppler lidar at 1.5 micrometres measuring wind velocity profiles to several kilometres. The sizing follows from applying the relevant intensity, thermal, nonlinear and geometric bounds at a single stated operating point, with every number produced by a deposited computation. The headline result is a range resolution of 30 m from the 200 ns pulse, an average transmitted power of 3.0 W, about 12 detected photons per gate at 3 km under the stated backscatter, a signal-to-noise ratio near 3, and a single-pulse velocity precision near 0.1 Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.