Answers are grounded in this paper and cite their sources.
Objective. Objective: to construct a binary incidence matrix for a formal analysis of diagnostic distinguishability of the electrical and thermal path contributions in a vertical SiC-SiT and to determine the minimum set of additional indicators required for their separation. Method. A 9×7 binary matrix A is defined for nine selected functional contributions and seven diagnostic indicators. Binary row signatures, an equivalence relation, and the number of distinguishability classes are introduced for a selected subset of indicators; the minimum additional set is formulated as a discrete subset-selection problem. Result. The integral set R_on,ref, R_th,ss, and Z_th(t) produces two classes, electrical and thermal. Adding four process-monitor indicators gives five distinct signatures for the electrical contributions; within the adopted matrix this additional set is minimal. For four thermal contributions, the combinatorial lower bound shows that at least two new binary indicators are required, provided that their sensitivity profiles are different. Conclusion. The binary matrix makes it possible to test the structural sufficiency of a diagnostic set before solving a quantitative inverse problem and to identify groups of parameters that remain indistinguishable.
No takes yet. Share an insight, caveat, or question.
T. I. Isabekova (2026) studied this question.