Answers are grounded in this paper and cite their sources.
Dental radiography is essential for diagnosis and treatment planning, but exposure to ionizing radiation requires strict adherence to radiation protection principles. This study evaluated radiation protection knowledge, self-reported compliance, and their associated factors among dental students, interns, and dentists. A cross-sectional study included 136 participants (86.1% response rate). A content-reviewed bilingual questionnaire assessed 7 knowledge items (6 scored in the composite knowledge score) and 12 self-reported compliance items. Pilot testing, translation, content validity (scale-level average content validity index [S-CVI/Ave] = 0.91), and internal consistency (α = 0.78; Kuder–Richardson Formula 20 [KR-20] = 0.70) were evaluated. Multivariable ordinary least squares regression examined factors associated with compliance using SPSS 27 and Python software. The composite knowledge score was 0.804; the pediatric radiation protection item had a correct-response rate of 54.4% (single-item assessment). Mean compliance was 3.09/4. Composite knowledge score was independently associated with self-reported compliance (B = 1.092, 95% confidence interval: 0.817–1.366, p < 0.001). Compliance was significantly lower among Year 5 students and interns than among Year 3 students (p = 0.037 and p = 0.005, respectively), whereas gender and the remaining training-level contrasts were not significant (R 2 = 0.360). Knowledge showed a moderate-to-strong positive correlation with compliance (rₛ= 0.528, p < 0.001). Exploratory analyses indicated a stronger knowledge–compliance association among more advanced trainees (Year 5, interns, and dentists/faculty) than among earlier-year students. The largest compliance gaps involved X-ray image repetition frequency, use of protective shielding devices, and motion-restraining tools. Composite knowledge score was independently associated with self-reported compliance, and adjusted compliance was lower among Year 5 students and interns than among Year 3 students. However, the cross-sectional design and reliance on self-reported data preclude causal interpretation. Lower compliance was observed for X-ray image repetition frequency, protective shielding devices, and motion-restraining tools. These findings support competency-based training and curriculum review, but recommendations remain exploratory and require confirmation in larger multi-institutional prospective studies.
No takes yet. Share an insight, caveat, or question.
Alsultan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: