Key result
Acute 30° renal artery take-off angle generates peak hemodynamic disturbance in computational models.
Computational fluid dynamics modeling demonstrates that renal artery take-off angle, blood rheology, and bilateral vascular coupling jointly produce non-monotonic hemodynamic changes, with the highest flow disturbance occurring at an acute 30° take-off angle.
Answers are grounded in this paper and cite their sources.
Acute renal artery angles may increase modeled flow disturbance; leaves open clinical relevance for renovascular disease.
Renal artery take-off geometry can alter renal and aortic hemodynamics. Transient CFD simulations were performed for a bilateral aorto–renal model in which the right renal artery angle was varied from \(30^∘ \) to \(150^∘ \) , while the left renal artery was fixed at \(60^∘ \) . Newtonian and Carreau–Yasuda rheology models were assessed using three-element RCR Windkessel outlet conditions. TAWSS, OSI, RRT, and a composite Renal Angle Hemodynamic Disturbance Index (RAHBI) were evaluated. The response was non-monotonic and region dependent. Globally, Newtonian TAWSS increased from 1.02 to \(2.66~Pa\) between \(30^∘ \) and \(60^∘ \) , while OSI decreased from 0.184 to 0.035 and RRT from 1.57 to \(0.41~ {Pa⁻¹}\) . In the varied right renal branch, Newtonian TAWSS increased from 8.50 to \(22.42~Pa\) between \(30^∘ \) and \(150^∘ \) . The highest RAHBI occurred at \(30^∘ \) , reaching 78.954 and 13.972 for the Newtonian and Carreau–Yasuda models, respectively; at \(150^∘ \) , the corresponding values were 0.205 and 6.000. The fixed left renal branch also changed, confirming bilateral coupling. Velocity-profile validation yielded \(R=0.999\) , and two-way fluid–structure interaction reduced global TAWSS by 4.52%. Alternative weighting, arithmetic, and RRT-free formulations consistently identified \(30^∘ \) as the highest-scoring varied-branch configuration; rank agreement with the baseline index was \(ρ _s=0.90\) –1.00. These computational findings indicate that renal angulation, rheology, and bilateral interaction should be interpreted jointly. RAHBI is a configuration-specific comparative measure, not a clinically validated risk metric.
No takes yet. Share an insight, caveat, or question.
Çutay et al. (2026) studied Aorto-renal hemodynamics (computational model). Right renal artery take-off angle variation (30° to 150°) in transient CFD simulations vs. Different angle configurations and Newtonian vs Carreau-Yasuda rheology models was evaluated on Renal Angle Hemodynamic Disturbance Index (RAHBI), TAWSS, OSI, and RRT. Varying the right renal artery angle from 30° to 150° produced peak hemodynamic disturbance (RAHBI) at 30° and altered TAWSS from 8.50 to 22.42 Pa.
Synapse has enriched 10 related papers. Consider them for comparative context: