Answers are grounded in this paper and cite their sources.
Sampling-time jitter makes a sampled-data control loop time-varying, so standard LTI robust-control synthesis does not apply directly. This paper reformulates dynamic output feedback design under bounded, unmeasured sample-to-sample jitter as a robust-control problem. The exact zero-order-hold model is decomposed into a nominal time-invariant plant and a memoryless, time-varying uncertainty block with a norm bound representing the sampling-time jitter. As the block is memoryless, the operator small-gain condition for the time varying loop reduces to a standard robustness test with a matrix norm bound. It is shown that the same test also guarantees uniform exponential stability for every admissible jitter sequence. Embedding the decomposition into a generalized plant with performance channels serves two synthesis objectives with standard robust-control tools: Robust stability with optimized nominal performance through structured H-inf synthesis, and robust performance through mu synthesis with constant scalings. A numerical example shows that jitter can destabilize a control loop with a nominal H-inf controller, whereas both robust designs remain stable and the robust-performance design is less sensitive to jitter at the cost of nominal performance.
No takes yet. Share an insight, caveat, or question.
Schwarzmann et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: