Greenhouses operating in hot, arid climates are exposed to large solar gains during the day and significant heat losses at night, which makes passive thermal buffering attractive. In this work, a north-wall storage layer made of the paraffin RT25 is embedded in aluminum, copper or steel foam, and its effect on the greenhouse microclimate is analyzed with a transient two-dimensional CFD model that couples porous-medium resistance, discrete-ordinates solar radiation, turbulent airflow and enthalpy–porosity phase change. Each composite is evaluated against an otherwise identical pure-RT25 wall. The simulated temperature, liquid-fraction, enthalpy and velocity fields show that the foam material modifies conductive heat spreading inside the wall, the timing of latent storage and the buoyancy-driven circulation in the enclosure. The thermal and phase-change results correspond to a 45 °C exterior/15 °C nighttime scenario, while the airflow profiles correspond to a separate 45 °C/10 °C scenario. A single foam pore density (20 PPI) is examined, so no pore-density optimum is claimed. Against a building-roof PCM experiment, the model reproduces the measured inner roof-surface temperature history with a root-mean-square error of 0.21 °C; this benchmark supports the thermal response of the PCM layer but not the complete greenhouse–foam system. Because no HVAC load balance is solved, the findings are expressed as comparative physical responses rather than as quantified energy savings.