Design blueprint derived from the source paper (DOI 10.5281/zenodo.24189062): This study sizes a loop heat pipe radiator array rejecting 50.0 kilowatts of habitat waste heat from panels at 310 kelvin: each square metre radiates 482 watts, so the array needs 104 square metres before margin and 130 square metres with the stated design margin, served by 34 transport loops at the stated per-loop capacity. Sizing follows from computed thermal budgets derived in the study. This is a computed study with no targeting or weapon application. The work is simulated and computed from stated assumptions, not measured. Status: DESIGN BLUEPRINT — SIMULATED, NOT MEASURED — NOT BUILT. All numbers are simulated values from the source paper's computation, deposited with this blueprint as compute.py and results.json. AI-use disclosure: Dave, an AI research system, assisted with the computation and drafting under the author's direction; author of record William Alexander Aldred.