Answers are grounded in this paper and cite their sources.
This study compares the seismic response of three reinforced concrete models of a G+15 building in ETABS. Model 1 is a frame without shear walls. Model 2 adds corner shear walls, and Model 3 combines corner shear walls with soft storeys reported at ground, fifth, and tenth floors. The comparison uses base shear magnitudes, peak storey drift ratios, and roof displacements under separate linear static earthquake cases in the X and Y directions. The frame-only model produced 23.9606 mm of roof displacement and a peak drift ratio of 0.000640 in each direction. Model 2 produced the lowest roof displacements, 11.711 mm and 11.698 mm, and the lowest peak drift ratios, 0.000292 and 0.000291. Model 3 produced roof displacements of 12.834 mm and 12.837 mm and a peak drift ratio of 0.000309 in both directions. Relative to the frame-only model, Model 3 reduced roof displacement by 46.4% and peak drift by 51.7%. Its reported base shear was approximately 2.98 times the frame-only value. Conflicting zone labels and storey elevations in the model documentation limit code-specific interpretation.
No takes yet. Share an insight, caveat, or question.
Shaikh et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: