Key result
FFR-CT accurately detects ischemia in severe AS with ~88% diagnostic accuracy vs. invasive FFR.
Why the study?
Computed tomography-derived fractional flow reserve (FFR-CT) is used to assess coronary artery disease, but its diagnostic performance had not been validated in patients with severe aortic stenosis.
Does computed tomography-derived fractional flow reserve (FFR-CT) accurately detect functional coronary ischemia compared to invasive FFR and safely allow deferral of invasive coronary angiography in patients with severe aortic stenosis undergoing TAVR?
Cohort (n=104)
Does computed tomography-derived fractional flow reserve (FFR-CT) accurately detect functional coronary ischemia compared to invasive FFR and safely allow deferral of invasive coronary angiography in patients with severe aortic stenosis undergoing TAVR?
Answers are grounded in this paper and cite their sources.
FFR-CT strongly correlates with invasive FFR with a 100% negative predictive value in severe aortic stenosis, supporting its potential role as a non-invasive gatekeeper to safely defer invasive coronary angiography before TAVR.
Background Computed tomography-derived fractional flow reserve (FFR-CT) is a clinical modality for assessing coronary artery disease; however, its use has not been validated in patients with severe aortic stenosis (AS). Purpose This study assessed the diagnostic performance of FFR-CT in patients with severe AS. Methods Retrospectively recruited patients with severe AS underwent standard-protocol invasive fractional flow reserve (FFR) and coronary CT angiography. The FFR-CT values were compared with the invasive FFR values (ischemia defined as invasive FFR ≦0.80). Results Among 46 patients (105 vessels), the mean age was 82.8 ± 5.9 years (37% male). Mean invasive FFR and FFR-CT values were 0.86 ± 0.11 and 0.83 ± 0.10, respectively. In a per-vessel analysis, there was a positive correlation between invasive FFR and FFR-CT values (Pearson correlation coefficient, R= 0.64; P<0.0001). In addition, the sensitivity, specificity, positive predictive, and negative predictive values were 100%, 86%, 43%, and 100% with 88% diagnostic accuracy, respectively. The Bland-Altman plot showed that the mean bias between invasive FFR and FFR-CT values was 0.031 (-0.146 to 0.209). The per vessels area under the receiver-operating characteristic curve analysis was 0.97 (95 % CI: 0.94-1.00, P<0.0001). Importantly, among another 58 patients who deferred invasive coronary angiography (ICA) because the FFR-CT value was negative (> 0.80), none experienced deterioration of condition during transcatheter aortic valve replacement (TAVR) or major adverse cardiac events (all-cause death, myocardial infarction, and unplanned hospitalization with urgent revascularization) within 30 days after TAVR. Conclusions FFR-CT values were significantly correlated with invasive FFR values and had a high negative predictive value in patients with severe AS. Patients with a negative FFR-CT value and deferred ICA had an excellent short-term prognosis after TAVR. FFR-CT is expected to serve as a gatekeeper for unnecessary ICA prior to TAVR.
No takes yet. Share an insight, caveat, or question.
Okayama et al. (2024) conducted a cohort in Severe aortic stenosis (n=104). Computed tomography-derived fractional flow reserve (FFR-CT) vs. Standard-protocol invasive fractional flow reserve (FFR <= 0.80 defining ischemia) was evaluated on Diagnostic performance of FFR-CT against invasive FFR <= 0.80 (per-vessel AUC, correlation, sensitivity, specificity, PPV, NPV, and diagnostic accuracy) (AUC 0.97, 95% CI 0.94-1.00, p=<0.0001). FFR-CT demonstrated high diagnostic performance for detecting ischemia against invasive FFR in severe AS.
Synapse has enriched 10 related papers. Consider them for comparative context: