Answers are grounded in this paper and cite their sources.
This study developed and evaluated an Internet of Things (IoT) prototype for monitoring electrical and temperature parameters of a 1,650 Wp nominal-capacity photovoltaic (PV) power plant, with a web-based dashboard. The system combines a PZEM-017 sensor for DC parameters, an MLX90614 infrared sensor for panel surface and ambient-area temperature, an ESP32 microcontroller, an LCD, and MQTT communication to the IoTKita dashboard. Readings are shown locally on the LCD and can be accessed remotely through the dashboard. The system was tested over five days by comparing its readings against a reference instrument. Because time-resolved data were not included in the test documentation, the comparison was made on average values. The relative differences from the reference instrument were 0.00% for voltage, 2.65% for current, 2.21% for power, 1.55% for panel surface temperature, and 0.51% for ambient-area temperature. The system recorded a cumulative energy of 14.67 kWh during the test period. The 0.00% voltage difference arises because both averages round to 120.9 V, so it should not be read as a measure of precision. These results indicate only a preliminary agreement at the level of averages. Sample-by-sample accuracy and long-term reliability cannot be concluded until the DC measurement point, data collection dates, and communication logs have been verified.
No takes yet. Share an insight, caveat, or question.
Saputra et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: