This study sizes the system named in its title from stated physical relations and a stated operating basis, and reports the result as SIMULATED, NOT MEASURED. The operating principle is electrical energy converted to heat and stored in a buried insulated regolith mass during power-rich periods, then recovered as habitat heating, trading conversion losses for very cheap storage mass. The system is a civilian heating store for a six-person Mars habitat, smoothing the gap between solar generation by day and heating demand by night. Every figure is computed by the deposited script from its inputs rather than asserted. At the design point the overburden pressure is 10.7 kilopascals, the dose at depth is 0.0286 millisieverts per day against 0.55 millisieverts per day at the surface, the excavated quantity is 403.0 cubic metres (645.0 tonnes), and the average power demand is 23.6 kilowatts with a steady heat loss of 6.21 kilowatts. Mass, power, thermal and construction budgets are assembled from components so they can be audited line by line, off-design behaviour is discussed openly, and the limits of the sizing are stated in full. The design is presented as a civilian system throughout, for use on the Mars, with its governing constraint identified and quantified rather than merely encountered.