Answers are grounded in this paper and cite their sources.
This research proposes a nonlinear piezoelectric admittance-based electromechanical fatigue monitoring framework to assess fatigue degradation in metallic structures continuously. The proposed methodology integrates cyclic fatigue loading, nonlinear admittance response measurement, feature extraction, fatigue state index formulation, relationship analysis, and experimental validation. Progressive fatigue loading was applied to the metallic specimen, and electromechanical admittance signatures were measured using a bonded piezoelectric transducer during the fatigue process. The admittance index increased from 10 to 95 with an increase in stress amplitude from 120 MPa to 220 MPa, demonstrating the sensitivity of the proposed index to progressive fatigue loading. The resonance frequency shift increased from 0.00 to 1.34 kHz, while the admittance variation index increased from 0.00 to 0.93 with fatigue progression. The normalized feature value and electromechanical fatigue state index increased from 0.08 to 1.00 and from 0.10 to 1.00, respectively. Experimental evaluation at fatigue-cycle levels ranging from 0 to 100 × 10³ cycles produced detection accuracy values between 90% and 99%, while monitoring sensitivity increased from 0.18 to 0.98. The results demonstrate the feasibility of nonlinear piezoelectric admittance features for quantitative fatigue-state assessment and continuous structural health monitoring of metallic structures.
No takes yet. Share an insight, caveat, or question.
Subramanian et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: