Answers are grounded in this paper and cite their sources.
This paper presents a computed design study of a cryogenic propellant depot whose operating principle is a thermodynamic vent system that controls tank pressure during storage and transfer without direct venting of liquid. The depot stores 11000 kilograms of liquid hydrogen at 20.3 kelvin in a spherical tank of radius 2.4 metres, with a computed heat leak of 0.941 watts, a boiloff rate of 0.1823 kilograms per day, a cryocooler power of 72.0 watts where active cooling is applied, and a transfer-line chilldown cost of 52.679 kilograms. All numbers are computed in the deposited script from stated inputs; nothing is measured. The study is for civilian in-space logistics only. It is a computed study with no targeting or weapon application, and no part of the design is adapted to any such use. The purpose is to show, with auditable arithmetic, whether this operating principle closes its thermal, fluid and power budgets for long-duration storage and transfer.
No takes yet. Share an insight, caveat, or question.
William Alexander Aldred (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: