Answers are grounded in this paper and cite their sources.
In field-based performance assessments, accurately monitoring athletes’ running pace is essential for reliable test results. The Yo-Yo Intermittent Recovery Level 1 (YIR1) test evaluates intermittent endurance, but inadequate auditory cues, environmental noise, and pacing errors may reduce consistency. The modular speed control and tracking system (INTimeSYS) effectively regulates running pace. This study aimed to examine validity and reliability of INTimeSYS-YIR1 test, which was developed by integrating with YIR1 protocol. Twenty-one football players (age = 15.70 ± 0.20 years, mass = 61.23 ± 4.79 kg, height = 173.71 ± 4.91 cm) participated in the study. The tests were administered in the following order: INTimeSYS-YIR1, YIR1, and INTimeSYS-YIR1. The reliability of the INTimeSYS-YIR1 test was assessed using single and average-measures intraclass correlation coefficients (ICCs), and criterion validity was evaluated with the Pearson correlation coefficient. Paired-samples t-tests and Bland-Altman plots assessed differences and agreement, respectively, between YIR1 and INTimeSYS-YIR1. The INTimeSYS-YIR1 test demonstrated good test-retest reliability based on average-measures ICCs for TD (ICC = 0.81) and FS (ICC = 0.82), moderate reliability for HR max (ICC = 0.69) and estimated VO₂max (ICC = 0.66), and poor reliability for Rating of Perceived Exertion (RPE) (ICC = -0.09) and LA (ICC = -0.16). Single-measure ICCs indicated moderate reliability for TD (0.69), FS (0.69), and HRmax (0.53), and poor reliability for estimated VO₂max (0.49), RPE (-0.05), and LA (-0.07). Criterion validity analyses showed significant positive correlations between YIR1 and INTimeSYS-YIR1 for TD ( r = 0.77, p < 0.001), FS ( r = 0.64, p = 0.002), estimated VO₂max ( r = 0.71, p < 0.001) and RPE ( r = 0.48, p = 0.028). Compared with YIR1, INTimeSYS-YIR1 mean resulted in significantly greater TD, FS, and estimated VO₂max and lower LA concentrations (all p < 0.001), whereas no significant difference was observed for RPE ( p = 0.218). INTimeSYS-YIR1mean yielded approximately 505.7 m greater TD than conventional YIR1, suggesting that protocols may produce different performance outcomes and that direct interchangeability warrants caution. INTimeSYS may support performance assessment in young male football players, although reliability depends on outcome and number of administrations. Broader applications require further validation.
No takes yet. Share an insight, caveat, or question.
Çetindemir et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: