Answers are grounded in this paper and cite their sources.
Asbestos contamination blocks gypsum recycling from demolition waste. Regulatory thresholds near 0.1 wt% lie well below the ~ 1 wt% limit of conventional X-ray powder diffraction. We evaluate machine-learning detection of trace chrysotile (0.001–9 wt%) in recycled gypsum from wide-angle X-ray scattering, comparing six feature representations under one Extra-Trees estimator on 1532 spectra from 373 samples, with group-aware splits and 18 seeds. Internally the representations are indistinguishable, so we report the minimum detectable difference (0.030–0.062) rather than a ranking. The untransformed spectrum is the strongest internal detector (AUC 0.9993 ± 0.0007 , zero false negatives at 9.4% false positives), yet misses all 16 measurements of a commercial fibre-cement board absent from training, which an unsupervised linear projection detects in full. Dimensionality reduction, not internal accuracy, determines whether a decision rule transfers to a new matrix. We therefore select on cross-matrix transfer, reporting a PCA model restricted to the diagnostic chrysotile reflections (accuracy 0.9450 ± 0.0187 ). A retained production sample independently assayed at 0.0201 wt%, one fifth of the regulatory threshold, and used in no selection step is identified as asbestos-bearing. Quantification remains semi-quantitative (log-MAE 0.62) and does not transfer across matrices, so the framework suits on-line screening in industrial recycling.
No takes yet. Share an insight, caveat, or question.
Wilhelm et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: