Much to the detriment of ultrasonic testing and all attempts at standardization, it is not yet possible to compare the results from different kinds of equipment regarding the echo of a back wall or a small defect. In order to facilitate this, the relations between echo height, distance and size of circular disk defect are brought into simple and universally applicable forms. It is shown that the first back echo of a simple plate is the most convenient reference echo. With the help of a calibrated gain control as accessory to a usual flaw detector and a graphical representation of the formulae, an equivalent circular disk defect can be attributed to the actual defect. The influence of curved contact and back wall surfaces, and the application of the method for determining ultrasonic attenuation in thick specimens, is discussed.