Answers are grounded in this paper and cite their sources.
Laboratory hydraulic-conductivity tests on sand-bentonite mixes were performed prior to the construction of a sand-bentonite liner near Trois-Rivieres. In some of the tests, the sand-bentonite mix was not structurally stable and bentonite appeared in the column effluent. This washing of the bentonite may occur with low contents of fines or bentonite. The hydraulic conductivity of the washed samples was equal to the hydraulic conductivity of the sand without bentonite. Published data are shown to be compatible with these findings. During liner construction, repetitive sampling of the sand-bentonite mix provided updated estimates of statistical parameters (mean and variance) of fines and bentonite contents. A simple statistical is based on the hydraulic-conductivity test results and the statistical parameters of fines content and bentonite content. Updated washing probability was used as a tool for quality control and successfully identified a problem during liner construction. Implications for the design, construction, and performance of sand-bentonite liners are discussed.
No takes yet. Share an insight, caveat, or question.
Marcotte et al. (1994) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: