Answers are grounded in this paper and cite their sources.
To this date, the characterization of Non-Insulated HTS coils for parameter estimation has been conducted using relatively slow current ramps. In the present work, a methodology based on AC signals is proposed to get additional parameters to refine the model of such coils and to improve on the existing lumed-parameter models for DC applications under dynamic responses. In that regard, two sets of sequential characterizations were conducted in liquid nitrogen at 77.3 K. First, a classical U(I) characterization in DC and different ramp tests were carried out to deduce the critical current ICC and the self-inductance of the NI coil. Second, AC measurements are performed at different frequencies and current magnitudes. From these last measurements, it was found that the lumped-parameter model best agreeing with experimental data is serial and not parallel as usually considered in DC. Thus, it further simplifies the equivalent electrical circuit of the NI HTS coils with a serial resistance RS connected in series with a serial inductance XS. Both electrical parameters can be directly obtained from voltage measurements and strongly depend on frequency but not the current amplitude in subcritical conditions. Ultimately, a lumped-parameter model is a useful approach to understand the behavior of NI HTS coils interacting with a more complex system or to study their response to transients in DC or DC+AC conditions.
No takes yet. Share an insight, caveat, or question.
Douine et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: