Key result
Bicuspid aortic valve linked to ~2-fold higher ascending aortic energy loss versus controls.
Why the study?
Altered aortic flow dynamics are observed in patients with bicuspid aortic valve (BAV), but their local energetic characteristics remain incompletely understood.
Does bicuspid aortic valve without significant valve dysfunction increase total and segmental aortic energy loss compared to matched controls?
Observational (n=32)
Does bicuspid aortic valve without significant valve dysfunction increase total and segmental aortic energy loss compared to matched controls?
Answers are grounded in this paper and cite their sources.
Patients with bicuspid aortic valve exhibit approximately twofold higher segmental ascending aortic energy loss on 4D flow CMR compared to matched controls even in the absence of significant valve dysfunction, though baseline energy loss was not linked to 10-year outcomes.
Background Altered aortic flow dynamics are observed in patients with bicuspid aortic valve (BAV), but their local energetic characteristics remain incompletely understood. The primary objective was to compare total and segmental energy loss (EL) between patients with BAV without significant valve dysfunction and matched controls. The subsequent clinical and structural course of the BAV cohort was described. Methods Sixteen patients with BAV and 16 matched controls underwent baseline four-dimensional flow cardiovascular magnetic resonance. Total and segmental aortic EL were quantified and normalized to flow. Commissural orientation was assessed. Clinical follow-up was available in all 16 patients with BAV, and paired baseline and approximately 10-year CMR assessments of aortic dimensions were available in 14. Results Mean flow-normalized EL was approximately twofold higher in patients with BAV from the sinus of Valsalva to proximal ascending aorta (0.78 [0.59–1.14] vs 0.40 [0.29–0.67] mW/[L/min]; P = 0.015) and from proximal to distal ascending aorta (1.26 [0.79–1.59] vs 0.64 [0.39–1.07] mW/[L/min]; P = 0.013). Commissural angle was not significantly associated with segmental EL. No major BAV-related cardiovascular complications occurred during follow-up. In paired examinations, maximum ascending aortic diameter increased from 3.40 ± 0.67 to 3.75 ± 0.67 cm (P < 0.001), whereas the body surface area-indexed increase was attenuated (1.88 ± 0.29 to 1.97 ± 0.33 cm/m 2 ; P = 0.056). Conclusions Segmental aortic EL was increased in patients with BAV despite the absence of significant valve dysfunction. The approximately 10-year follow-up provides descriptive clinical and structural characterization but does not establish a relationship between baseline EL and subsequent outcomes.
No takes yet. Share an insight, caveat, or question.
Harada et al. (2026) conducted an observational in Bicuspid aortic valve (n=32). Bicuspid aortic valve vs. Matched controls was evaluated on Total and segmental flow-normalized aortic energy loss (EL) (p=0.013). Bicuspid aortic valve patients had higher flow-normalized energy loss than controls in the proximal and distal ascending aorta.