Key result
Preoperative cardiac CT accurately predicts aortic cusp free margin length before valve-sparing root replacement.
Why the study?
Determining the feasibility of valve-sparing aortic root replacement (VSRR) requires accurate preoperative assessment of aortic valve cusp geometry, but the reliability of computed tomography (CT) for measuring cusp parameters and predicting intraoperative cusp plication remained unclear.
Does preoperative cardiac CT accurately measure aortic valve cusp parameters compared to direct intraoperative measurements and predict the need for intraoperative cusp plication in patients undergoing valve-sparing aortic root replacement?
Cohort (n=32)
Radiologist blinded to echocardiographic and clinical data; operating surgeon blinded to preoperative CT-derived cusp measurements
No
Does preoperative cardiac CT accurately measure aortic valve cusp parameters compared to direct intraoperative measurements and predict the need for intraoperative cusp plication in patients undergoing valve-sparing aortic root replacement?
Answers are grounded in this paper and cite their sources.
Preoperative cardiac CT reliably measures aortic valve cusp free margin length in tricuspid valves compared to direct intraoperative assessment, supporting its utility in preoperative planning for valve-sparing aortic root replacement.
Purpose Determining the feasibility of valve-sparing aortic root replacement (VSRR) requires accurate preoperative assessment of aortic valve cusp geometry. However, the reliability of computed tomography (CT) for measuring cusp parameters remains unclear. This study evaluated the agreement between CT-derived cusp measurements and intraoperative measurements and explored the potential of CT-based cusp asymmetry to predict intraoperative cusp plication. Materials and Methods In this prospective study, 32 consecutive patients undergoing VSRR with the reimplantation technique were enrolled. Preoperative CT was used to measure cusp free margin length and geometric height. Agreement between CT-derived and intraoperative measurements was assessed using Bland–Altman analysis and intraclass correlation coefficients (ICCs). An exploratory analysis evaluated whether CT-derived cusp asymmetry predicted the need for intraoperative cusp plication. Results CT measurements demonstrated good agreement with intraoperative measurements for cusp free margin length (ICC 0.80–0.87). In contrast, geometric height showed only moderate agreement (ICC 0.44–0.69). Exploratory receiver operating characteristic analysis demonstrated moderate discriminative ability of CT-derived cusp asymmetry for predicting intraoperative cusp plication (area under the curve, 0.71; 95% confidence interval, 0.49–0.91), although the association did not reach statistical significance (p=0.06). Postoperative echocardiography demonstrated none-to-mild aortic insufficiency in 96.9% of patients. Conclusion Preoperative CT demonstrated good agreement with intraoperative measurements for cusp free margin length in tricuspid valves, although the absolute limits of agreement were wide. CT-based quantification of cusp asymmetry may provide additional information for preoperative surgical planning; however, its association with intraoperative cusp plication remains exploratory and requires validation in larger studies. Clinical Research Information Service (CRIS) registration number KCT0006180
No takes yet. Share an insight, caveat, or question.
Kim et al. (2026) conducted a cohort in Aortic root aneurysm or aortic regurgitation attributable to annuloaortic ectasia (n=32). Preoperative three-dimensional ECG-gated cardiac CT measurement of aortic valve cusp geometry (free margin length and geometric height) vs. Direct manual intraoperative cusp measurements using a surgical ruler under gentle traction was evaluated on Agreement between preoperative CT-derived and direct intraoperative measurements of aortic valve cusp parameters (free margin length and geometric height) (ICC 0.80-0.87 for free margin length; ICC 0.44-0.69 for geometric height).
Synapse has enriched 10 related papers. Consider them for comparative context: