Key result
Surgical AVR with concomitant CABG successfully treats rare unicuspid aortic valve in an older adult.
Why the study?
Unicuspid unicommisural aortic valves are rare anomalies with a 0.02% prevalence that typically precipitate congenital aortic stenosis in the 4th-6th decades of life, making symptomatic manifestation in a septuagenarian unusual.
Case Report (n=1)
No
Highlights a rare presentation of congenital unicuspid unicommisural aortic valve manifesting symptomatically in the eighth decade of life, successfully managed with concomitant surgical AVR and CABG.
Answers are grounded in this paper and cite their sources.
Successful concomitant AVR+CABG feasible in symptomatic septuagenarian; leaves open optimal strategies and outcomes for this rare valve in larger cohorts.
A 75-year-old woman presenting with dyspnea and chest pain underwent cardiac catheterization revealing three-vessel coronary artery disease with severe calcific aortic stenosis and dilated aortic root (Figure 1). A multi-gated acquisition scan (MUGA) was performed revealing LVEF to be 50%, reassuring consensus to proceed with aortic valve replacement and concomitant coronary artery bypass grafting. She was brought to the cardiovascular operating room (CVOR) in stable condition. Routine cardioplegia ensued after placement on cardiopulmonary bypass and grafting was performed to the obtuse marginal, posterior descending, and left anterior descending arteries. Upon successful grafting, attention shifted to the aorta. A transverse incision was made 2cm above the annulus, exposing the valve. A severely thickened, unicuspid, unicommisural aortic valve was observed (Figure 2) and replaced with a 23mm Edwards ® Inspiris TM valve. Unicuspid unicommisural aortic valves are rare manifestations with a prevalence of 0.02% 1 . They precipitate congenital aortic stenosis in patients within the first 4th-6th decades of life 2 . Outcomes are promising with aortic valve replacement 3 . Herein, we showcase this anomaly manifesting symptomatically in a septuagenarian, with successful surgical replacement and coronary bypass grafting.
No takes yet. Share an insight, caveat, or question.
Patel et al. (2024) conducted a case report in Severe calcific aortic stenosis with unicuspid unicommisural aortic valve and three-vessel coronary artery disease (n=1). Surgical aortic valve replacement (23mm bioprosthetic valve) and concomitant coronary artery bypass grafting was evaluated on Successful surgical aortic valve replacement and coronary bypass grafting. Surgical aortic valve replacement with a 23mm bioprosthetic valve and concomitant CABG successfully treated a rare unicuspid unicommisural aortic valve in a 75-year-old woman.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: