Answers are grounded in this paper and cite their sources.
This paper presents a computed design for an expendable falling temperature probe at an underway survey route between ports, operating on the following principle: a small probe is dropped from a moving ship and falls at a predictable rate while a fine wire unreels from both probe and ship, carrying its temperature signal back until the wire breaks, so depth is inferred from elapsed time and a calibrated fall-rate equation with no recovery of the probe. The fall-rate equation places the probe at 760 metres after 118 seconds, with a depth uncertainty of about 17 metres from the adopted fall-rate tolerance; a 48 probe line at 12 knots spaces profiles 17 kilometres apart and consumes its whole instrument budget in a single transit, by design. Expendability is the principle, not a compromise: by surrendering the probe, the survey gains a moving ship, no winch, no station time and a section completed in hours, and the budgets price that exchange in depth accuracy, wire behaviour and cost per profile. All sizing follows from computed buoyancy, pressure-hull, acoustic-link where carried, energy-endurance and sensor-drift budgets, each worked in the deposited calculation script from stated inputs. The study is a design exercise for civilian ocean science; it is simulated, not measured, and no part of it concerns any weapon or targeting application.
No takes yet. Share an insight, caveat, or question.
William Alexander Aldred (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: