Answers are grounded in this paper and cite their sources.
In non-local garnet devices a platinum strip injects magnons electrically, they diffuse through the insulating film without any charge motion, and a second platinum strip microns away converts their arrival back into a voltage, with the signal decaying over a characteristic length of several micrometres at room temperature. Diffusive magnon transport obeys the same square-root arithmetic as any random walk with a finite lifetime: the relaxation length follows from multiplying the diffusion constant by the spin lifetime and taking the root, the signal at a given separation falls as the exponential of minus separation over that length, and the transit time across a gap grows with the square of the distance divided by the diffusion constant. Headline values are diff relaxation length um diffusion = 8; diff constant cm2 per s diffusion = 3.2; diff signal at 5um fraction diffusion = 0.5353; diff signal at 20um fraction diffusion = 0.08208; diff signal at 40um fraction diffusion = 0.006738; diff time across 10um us diffusion = 0.3125. Decay fractions at named separations are the observable-facing entries; the length itself is inferred, and the text keeps that distinction visible.
No takes yet. Share an insight, caveat, or question.
William Alexander Aldred (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: