The subject is a axial unit mounted in an inverted-U siphon over a flood bank proposed for a river flood bank protecting low farmland. The machine works as follows: the turbine sits inside a siphon that passes over a flood bank or weir crest, so generation needs no breach in the bank: a vacuum pump primes the siphon, water flows up one leg, through the runner and down the other, and breaking the vacuum stops the plant instantly. Pressure head at the crest holds at 7.39 metres, leaving 7.15 metres above vapour pressure, priming costs about 6 kilowatt-hours per start, and the plant delivers 57 kilowatts net. Cutting a powerhouse through a flood bank is often the one thing a flood authority will not permit, and the siphon layout exists for exactly that refusal. Its governing budget is not efficiency but the pressure at the crest: let it fall toward vapour pressure and the water column separates, the siphon breaks and the plant stops. This study computes the crest pressure with its margins and sizes the unit around it. Head, flow, efficiency and cavitation budgets, with a storage budget added for designs that bank energy, determine the whole sizing; the deposited script performs the arithmetic from the inputs it declares. Computed, not measured, and intended solely for civilian electricity supply, the design has no connection with any weapon or targeting purpose.
No takes yet. Share an insight, caveat, or question.
William Alexander Aldred (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: