Answers are grounded in this paper and cite their sources.
A flux rope carrying a filament has an axial field near thirty gauss, an azimuthal component at its edge near fifteen gauss, a length of a few hundred megametres and a radius near ten megametres. The end-to-end twist of a rope is its length times the azimuthal field divided by the product of radius and axial field, and comparing that twist with the line-tied kink threshold near one and a quarter turns, together with the Alfvén transit time along the rope, decides whether the configuration sits inside or outside the kink-stable domain. Headline values are twist total twist rad twist = 15; twist total turns twist = 2.387; twist kink threshold turns twist = 1.25; twist margin in turns twist = 1.137; twist safety factor q twist = 0.4189; twist axial alfven speed m per s twist = 2.676e+05. At two and four tenths turns end to end, the adopted rope exceeds the line-tied kink threshold by nearly a factor of two, so its survival depends on the stabilising weight of the filament mass and the restraint of the overlying arcade rather than on twist alone.
No takes yet. Share an insight, caveat, or question.
William Alexander Aldred (2026) studied this question.