Key result
Updated AUC improves appropriateness for TTE, TEE, and CTA, but not stress testing.
Why the study?
Appropriate use criteria for cardiac imaging have been available for almost 10 years, yet the extent to which their promulgation has led to a reported improvement in the proportion of appropriate cardiac imaging requests was undefined.
Does the promulgation of new appropriate use criteria (AUC) improve the proportion of appropriate cardiac imaging requests over time?
Meta-Analysis (n=103,567)
Does the promulgation of new appropriate use criteria (AUC) improve the proportion of appropriate cardiac imaging requests over time?
Promulgation of updated appropriate use criteria was associated with improved rates of appropriate testing for TTE, TEE, and cardiac CTA, but did not improve appropriateness for stress echocardiography or SPECT.
Answers are grounded in this paper and cite their sources.
Improvements in appropriate use remain inconsistent across modalities; leaves open whether AUC dissemination meaningfully curbs unnecessary imaging.
Background Appropriate use criteria (AUC) for cardiac imaging have been available for almost 10 years. The extent to which there has been a reported improvement in appropriate use is undefined. Objectives This study systematically reviewed published evidence to identify whether the promulgation of AUC has led to an improvement in the proportion of appropriate cardiac imaging requests. Methods Electronic databases were systematically searched for English-language papers related to AUC and cardiovascular imaging. We found 59 reports involving 103,567 tests that were published from 2000 to 2012. The rate of appropriate testing over time was analyzed in a meta-regression. Results New AUC were associated with apparent improvements in appropriateness for transthoracic echocardiography (TTE) (80% [95% confidence interval (CI): 0.75 to 0.84] vs. 85% [95% CI: 0.81 to 0.89]), transesophageal echocardiography (TEE) (89% [95% CI: 0.81 to 0.94] vs. 95% [95% CI: 0.93 to 0.96]) and computed tomography angiography (CTA) (37% [95% CI: 0.21 to 0.55] vs. 55% [95% CI: 0.44 to 0.65]) but not stress echocardiography (53% [95% CI: 0.45 to 0.61] vs. 52% [95% CI: 0.42 to 0.61]) or single-photon emission computed tomography (72% [95% CI: 0.66 to 0.77] vs. 68% [95% CI: 0.60 to 0.74]). Although there were no correlations between the proportion of appropriate TTEs and published year (p = 0.36) for 2007 AUC, there was a positive correlation between proportion of appropriateness and the year of publication (p = 0.01) for 2011 AUC. There was a significant decrease in the proportion of appropriateness over time using the 2007 TEE AUC (p = 0.03) and 2006 CT AUC (p = 0.02). There were no meaningful associations between appropriateness and publication year for stress echocardiography, CTA, or single-photon emission computed tomography. Conclusions Rates of reported appropriate use in imaging show improvements for TTE and CTA but not for stress imaging and TEE. The observed reductions in imaging studies are not matched by reported rates of appropriate use.
No takes yet. Share an insight, caveat, or question.
Fonseca et al. (2015) conducted a meta-analysis in Cardiovascular imaging requests (n=103,567). New appropriate use criteria (AUC) for cardiac imaging vs. Earlier appropriate use criteria (AUC) versions was evaluated on Proportion of appropriate cardiac imaging requests over time. New appropriate use criteria improved appropriateness for TTE, TEE, and CTA, but not stress echo or SPECT.