Answers are grounded in this paper and cite their sources.
Objective Wearable physiological monitoring faces major challenges, including the high susceptibility of photoplethysmography (PPG) signals to motion artefacts, limited accuracy of anomaly detection, and insufficient engineering deployability of existing methods. To address these issues, this paper proposes an integrated engineering software framework based on multi-source coupling. The study aims to improve monitoring reliability by balancing signal quality enhancement and anomaly detection performance, while also considering system practicality in complex dynamic scenarios. Methods Multi-source sensor data from PPG and inertial measurement unit (IMU) signals were used to establish a unified signal observation and interference modelling mechanism. A multi-task collaborative framework was developed to integrate signal reconstruction and anomaly detection within a single architecture. Shared feature encoding and a multi-branch reconstruction module were employed to suppress motion artefacts, while a quality-aware classification mechanism was introduced to improve the robustness of cardiac rhythm anomaly detection. In addition, a parametric PPG simulation dataset covering different heart rates, rhythm abnormalities, and motion interference scenarios was constructed. Comparative experiments were conducted against traditional methods, single-task models, and serial approaches on a unified experimental platform. Results The proposed method achieved an SNR improvement of 11.2–13.6 dB under input signal-to-noise ratios (SNRs) of 5–15 dB, outperforming the comparison methods. In the anomaly detection task, the model achieved an accuracy of 92.8% and an F1-score of 0.91, improving by approximately 3.9% and 0.05, respectively, over the serial approach. Recognition rates for all categories exceeded 90%, with the Noise category achieving 92.6%. In addition, the model required only 28 ms for inference and 6.5 MB of memory, indicating that it satisfies the real-time operational requirements of wearable devices. Ablation experiments further confirmed the effectiveness of IMU assistance and multi-task collaboration. Conclusion The proposed engineering software framework for multi-source coupled PPG signal processing and anomaly detection achieves a favourable balance among signal cleaning capability, classification performance, and operational efficiency. It effectively improves the reliability of physiological monitoring in complex motion environments and provides an engineering-feasible solution for wearable health monitoring systems. The framework also shows potential for future extension to multimodal fusion and edge intelligence applications.
No takes yet. Share an insight, caveat, or question.
Wu et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: