Key result
2D and 3D TEE parameters strongly predict PBMV procedural success with AUCs up to ~0.95.
Why the study?
The study aimed to identify quantitative morphological parameters that predict procedural success and de novo or worsening MR after PBMV, and to define the role of 3D TEE in mitral valve assessment.
Does 3D TEE quantitative morphological assessment improve the prediction of procedural success and post-procedural mitral regurgitation compared with 2D TEE in patients with severe rheumatic mitral stenosis undergoing PBMV?
Cohort (n=85)
Yes
Does 3D TEE quantitative morphological assessment improve the prediction of procedural success and post-procedural mitral regurgitation compared with 2D TEE in patients with severe rheumatic mitral stenosis undergoing PBMV?
Quantitative 2D and 3D TEE morphological parameters provide high discriminatory accuracy (AUC 0.863–0.946) for predicting procedural success in patients undergoing percutaneous balloon mitral valvuloplasty for severe rheumatic mitral stenosis.
Answers are grounded in this paper and cite their sources.
May aid PBMV candidate selection via TEE parameters; hypothesis-generating and requires prospective validation before changing practice.
Background and Objectives The aim of this study is to find out quantitative morphological parameters that could be helpful in prediction of success and development of de novo or worsening MR after PBMV, and to define the role of 3D TEE in mitral valve assessment. Methods This prospective cohort study was conducted on 85 patients, age >18 years old, of both sexes, presented to (NHI) and Fayoum University hospital with isolated severe rheumatic MS with Wilkins' score <12, and nonexisting or mild mitral insufficiency; who then underwent PBMV in the period from August 2021 to May 2023. Exclusion criteria: Any contraindication or unfavorable clinical characteristics for PMV or for TEE. Results The ROC curve analysis revealed noteworthy insights into the predictive capabilities of the measured parameters. In the context of 2-D TEE measurements, the P/A LLR, CAR, and DH emerged as robust predictors of procedural success. The high Area Under the Curve (AUC) values for these parameters (0.931, 0.929, and 0.946, respectively) indicated their strong discriminatory power. Furthermore, the significant p-values (<0.001) underscored the statistical significance of these associations. These findings suggest that these 2-D TEE parameters can serve as valuable tools for anticipating the success of the targeted cardiac intervention. The 3-D TEE measurements also exhibited promising predictive potential. Notably, P/A LLR, CAR, and Ca score demonstrated varying levels of accuracy as predictors of procedural success. While all three parameters exhibited strong AUC values (0.929, 0.930, and 0.863, respectively), the significance of their associations (P < 0.001) emphasized their predictive relevance. These findings highlight Conclusions In conclusion, the study's findings underscore the potential of echocardiographic measurements as predictive markers for BMV procedural success. 3D TEE has added value over 2D TEE. The utility of 3-D TEE measurements is complementing the predictive capacity of 2-D TEE parameters.
No takes yet. Share an insight, caveat, or question.
Elbagoury et al. (2026) conducted a cohort in Isolated severe rheumatic mitral stenosis (n=85). 3D and 2D transesophageal echocardiography (TEE) and transthoracic echocardiography (TTE) morphological parameters vs. 2D TEE parameters was evaluated on Prediction of PBMV procedural success and development of de novo or worsening mitral regurgitation (MR) (AUC 0.929-0.946 (2D TEE) and AUC 0.863-0.930 (3D TEE), p=<0.001). 2D and 3D TEE morphological parameters strongly predicted PBMV procedural success, with AUCs up to 0.946 for 2D TEE and 0.930 for 3D TEE.
Synapse has enriched 10 related papers. Consider them for comparative context: