Key result
Smaller ulnar artery diameter is linked to ~95% lower odds of avoiding digital ulcers in systemic sclerosis.
Why the study?
The clinical utility of radial and ulnar artery diameter measurements using vascular ultrasonography as a simple screening method for vasculopathy in systemic sclerosis needed evaluation.
Does radial and ulnar artery diameter measurement using vascular ultrasonography identify systemic vasculopathy (digital ulcers and pulmonary hypertension) in patients with systemic sclerosis?
Case-Control (n=59)
Does radial and ulnar artery diameter measurement using vascular ultrasonography identify systemic vasculopathy (digital ulcers and pulmonary hypertension) in patients with systemic sclerosis?
Answers are grounded in this paper and cite their sources.
Vascular ultrasonography measurement of ulnar artery diameter provides a simple, non-invasive screening tool that correlates with digital ulcers and pulmonary hypertension in patients with systemic sclerosis.
Background This study aimed to evaluate the clinical utility of radial and ulnar artery diameter measurements using vascular ultrasonography (US) as a simple screening method for vasculopathy in systemic sclerosis (SSc). Methods We retrospectively reviewed patients with SSc who underwent vascular US between October 2023 and March 2024. Age- and sex-matched rheumatoid arthritis (RA) patients were included as disease controls. The radial and ulnar arteries were assessed at the wrist, and structural and hemodynamic parameters were analyzed. Associations with digital ulcers (DUs) and internal organ involvement were evaluated using logistic regression. Results Forty-seven patients with SSc (45 women, 96%) and 12 RA controls were included. The median age and disease duration were 74 years and 6.2 years, respectively. Pulmonary hypertension (PH) was present in 9 (19%), and 21 (45%) had a history of DUs. Median radial and ulnar artery diameters were significantly smaller in SSc than in RA (1.72 vs. 1.97 mm; 1.05 vs. 1.45 mm, respectively). Ulnar artery occlusion was detected in 4 SSc patients (9%). Smaller radial and ulnar diameters were associated with DUs (OR = 0.12 and 0.05, respectively). Cutoff values of 0.97 mm and 0.82 mm for ulnar artery diameter predicted DUs and PH, respectively (AUCs 0.724 and 0.721). Low BMI (< 18.5) and disease duration ≥ 5 years were significantly associated with ulnar artery narrowing. Conclusions Ulnar artery diameter measured by vascular US may serve as a simple and clinically accessible marker of systemic vasculopathy in SSc, with potential relevance to DUs and PH.
No takes yet. Share an insight, caveat, or question.
Fujita et al. (2026) conducted a case-control in Systemic sclerosis (SSc) (n=59). Radial and ulnar artery diameter measurement via vascular ultrasonography vs. Age- and sex-matched rheumatoid arthritis (RA) controls was evaluated on Association of ulnar artery diameter with digital ulcers (DUs) (OR 0.05). Smaller ulnar and radial artery diameters on vascular ultrasound were associated with digital ulcers in systemic sclerosis.
Synapse has enriched 10 related papers. Consider them for comparative context: