Key result
Fluoroscopy-only LAAO matches TEE guidance for implantation success while shortening procedural times.
Why the study?
Does fluoroscopy-only guidance provide comparable safety and efficacy to transesophageal echocardiography (TEE) guidance in patients undergoing left atrial appendage occlusion?
Cohort (n=759)
No
Does fluoroscopy-only guidance provide comparable safety and efficacy to transesophageal echocardiography (TEE) guidance in patients undergoing left atrial appendage occlusion?
Fluoroscopy-only guided left atrial appendage occlusion appears as feasible and safe as TEE-guided LAAO with significantly shorter procedure times in experienced centers, though disk-type devices require more fluoroscopic views than plug-type devices.
Answers are grounded in this paper and cite their sources.
Fluoroscopy-only LAAO may be feasible in selected patients; leaves open equivalence to TEE guidance without randomized trials.
Fluoroscopy alone is emerging as a guidance modality for left atrial appendage occlusion (LAAO). This study evaluated the safety and efficacy of fluoroscopy-only vs transesophageal echocardiography (TEE)-guided LAAO and compared the fluoroscopic views required for plug-type and disk-type devices. In this retrospective single-center cohort study, patients undergoing LAAO guided by fluoroscopy only or by TEE with fluoroscopy were divided into a fluoroscopy-only group (n = 603) and a TEE group (n = 156) and further into a fluoroscopy-only disk-type (FODT) (n = 382), fluoroscopy-only plug-type (n = 221), TEE disk-type (n = 76), and TEE plug-type (n = 80) subgroups. Follow-up included TEE at 3 to 6 months and clinical event monitoring. The fluoroscopy-only group exhibited comparable implantation success (99.8% vs 100%; P = 1.000), peridevice leak rates (≥3 mm: 1.0% vs 1.3%; P = 0.671) and clinical outcomes during follow-up to the TEE group, with significantly shorter LAAO procedure times (40.9 ± 21.7 vs 78.9 ± 35.0 min; P < 0.001). The FODT subgroup required more views under fluoroscopy (3 [3, 3] vs 2 [2, 3]; P < 0.001) despite comparable peridevice leak rates. The clinical outcomes were similar between the TEE and fluoroscopy-only groups and between the FODT and fluoroscopy-only plug-type subgroups. Whether a disk-type or plug-type device is employed, LAAO guided by fluoroscopy only appears to be as feasible and safe as guidance by TEE. However, disk-type device needed more fluoroscopy views for accurate implantation than plug-type device. In the absence of randomized data, these hypothesis-generating findings should not be extrapolated to less experienced operators or centers.
No takes yet. Share an insight, caveat, or question.
Pan et al. (2026) conducted a cohort in Patients undergoing left atrial appendage occlusion (LAAO) (n=759). Fluoroscopy-only guided left atrial appendage occlusion (LAAO) vs. Transesophageal echocardiography (TEE)-guided LAAO was evaluated on Implantation success (p=1.000). Fluoroscopy-only LAAO had comparable implantation success and peridevice leak ≥3 mm to TEE guidance, with shorter procedure times.
Synapse has enriched 10 related papers. Consider them for comparative context: